<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "https://jats.nlm.nih.gov/publishing/1.3/JATS-journalpublishing1-3.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:ali="http://www.niso.org/schemas/ali/1.0/" article-type="research-article" dtd-version="1.3" xml:lang="en">
<front>
<journal-meta>
<journal-id journal-id-type="publisher-id">gcj3</journal-id>
<journal-title-group><journal-title>Hydrospatial Analysis</journal-title></journal-title-group>
<issn publication-format="electronic">2582-2969</issn>
<publisher><publisher-name>Gatha Cognition</publisher-name></publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="doi">10.21523/gcj3.17010104</article-id>
<article-id pub-id-type="publisher-id">gca24</article-id>
<article-categories><subj-group subj-group-type="heading"><subject>Original Research Paper</subject></subj-group></article-categories>
<title-group><article-title>Spatial Variation of Aquifer Parameters from Coastal Aquifers of Sindhudurg District Maharashtra Using Pore-water Resistivity and Bulk Resistivity</article-title></title-group>
<contrib-group>
<contrib contrib-type="author"><name><surname>Naidu</surname><given-names>Suneetha</given-names></name><xref ref-type="aff" rid="aff1"/></contrib>
<contrib contrib-type="author"><name><surname>Gupta</surname><given-names>Gautam</given-names></name><xref ref-type="aff" rid="aff2"/></contrib>
</contrib-group>
<aff id="aff1"><institution>Indian Institute of Geomagnetism Kalamboli Highway New Panvel (W) Navi Mumbai 410218 Maharashtra</institution></aff>
<aff id="aff2"><institution>Indian Institute of Geomagnetism, Kalamboli Highway, New Panvel (W), Navi Mumbai - 410218 (India).</institution></aff>
<pub-date publication-format="electronic" date-type="pub"><day>09</day><month>01</month><year>2018</year></pub-date>
<volume>1</volume>
<issue>1</issue>
<fpage>28</fpage><lpage>40</lpage>
<history><date date-type="received"><day>26</day><month>12</month><year>2017</year></date><date date-type="rev-recd"><day>26</day><month>12</month><year>2017</year></date><date date-type="accepted"><day>02</day><month>01</month><year>2018</year></date></history>
<permissions><copyright-year>2018</copyright-year><license license-type="open-access" xlink:href="https://creativecommons.org/licenses/by-nc-nd/4.0/"><ali:license_ref>https://creativecommons.org/licenses/by-nc-nd/4.0/</ali:license_ref><license-p>This is an open access article distributed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License (CC BY-NC-ND 4.0).</license-p></license></permissions>
<self-uri xlink:href="https://gathacognition.com/article/gca24/spatial-variation-of-aquifer-parameters-from-coastal-aquifers-of-sindhudurg-district-maharashtra-using-pore-water-resistivity-and-bulk-resistivity"/>
<self-uri content-type="pdf" xlink:href="https://gathacognition.com/uploads/admin/articlefiles/GCJ3M171.pdf"/>
<abstract>
<p>Estimation of hydraulic parameters in coastal aquifers is an important task in groundwater resource assessment and development. An attempt is made to estimate these parameters using geoelectrical data in combination with pore-water resistivity of existing wells. In the present study, 29 resistivity soundings were analysed along with 29 water samples, collected from the respective dug wells and boreholes, in order to compute hydraulic parameters like formation factor, porosity, hydraulic conductivity and transmissivity from coastal region of north Sindhudurg district, Maharashtra, India. The result shows some parts of the study area reveal relatively high value of hydraulic conductivity, porosity and transmissivity. Further, a negative correlation is seen between hydraulic conductivity and bulk resistivity. The hydraulic conductivity is found to vary between 0.014 and 293 m/day, and the transmissivity varied between 0.14 and 11,722 m<sup>2</sup>/day. The transmissivity values observed here are in good correspondence with those obtained from pumping test data of Central Ground Water Board. These zones also have high aquifer thickness and therefore characterize high potential within the water-bearing formation. A linear, positive relationship between transverse resistance and transmissivity is observed, suggesting increase in transverse resistance values indicate high transmissivity of aquifers. These relations will be extremely vital in characterization of aquifer system, especially from crystalline hard rock area.</p>
</abstract>
<kwd-group kwd-group-type="author"><kwd>Maharashtra</kwd><kwd>Resistivity Sounding</kwd><kwd>Transmissivity</kwd><kwd>Porosity</kwd><kwd>Hydraulic Conductivity</kwd><kwd>Coastal Aquifers</kwd></kwd-group>
</article-meta>
</front>
<body>
<sec id="s1"><title>Introduction</title>
<p>Groundwater is the most prominent natural resource for human life. Excessive groundwater withdrawals have caused encroachment of seawater into the fresh water regions of coastal aquifers, resulting in a worldwide seawater intrusion problem (<xref ref-type="bibr" rid="R964">Werner <italic>et al., </italic>2013</xref>). Due to rapid growth in population and agriculture, the exploitation of groundwater resources is expanding globally and therefore a cumulative need is required in the field of groundwater management especially in ecologically affected areas. This is more essential due to saline water ingress into coastal aquifers, causing serious concerns in terms of both environmental and economic impacts (<xref ref-type="bibr" rid="R963">Werner, 2010</xref>; <xref ref-type="bibr" rid="R955">Shi and Jiao, 2014</xref>). In view of this fact, assessable description of the aquifers has become important in order to address most of the hydrological and hydrogeological problems. Formation factor (<italic>F<sub>a</sub></italic>), porosity (<italic>ϕ</italic>), hydraulic conductivity (<italic>k</italic>) and transmissivity (<italic>T</italic>) are the fundamental properties describing the subsurface hydrology. Usually hydraulic parameters of the aquifers are calculated from pumping tests. However, it is very expensive and time consuming to drill the wells at every location. Besides, the pumping test method yields results appropriate only to a small section of the aquifer. Therefore, better parameter characterization methods are adopted to study the aquifer parameters, especially in hard rock regions.</p>
<p>Surface geophysical methods may contribute substantially towards aquifer characterization. Geoelectrical method, especially the Vertical Electrical Sounding (VES) is a relatively economical, quantitative and non-invasive technique used for locating sites/depths for groundwater exploitation. Besides, it is used as an effective tool for ascertaining the subsurface geological framework of an area to solve or detect the hydrological, geological and geo technical problems (<xref ref-type="bibr" rid="R961">Ward, 1990</xref>). The potential benefits of this method in hydrogeological site characterization and aquifer mapping have been stated in numerous studies (<xref ref-type="bibr" rid="R938">Kelly, 1977</xref>; <xref ref-type="bibr" rid="R935">Huntley, 1986</xref>; <xref ref-type="bibr" rid="R944">Niwas and de Lima, 2003</xref>; <xref ref-type="bibr" rid="R924">Cassidy <italic>et al.,</italic> 2014</xref>; <xref ref-type="bibr" rid="R928">Das <italic>et al., </italic>2016</xref>). It is used routinely for aquifer zone delineation and evaluation of the aquifer characteristics. Since a correlation exists between hydraulic and electrical properties, as both properties are related to the pore space structure and heterogeneity (<xref ref-type="bibr" rid="R949">Rubin, 2003</xref>), an integration of aquifer parameters calculated from boreholes and surface resistivity parameters is a viable solution to estimate the hydraulic parameters.</p>
<p>Several investigators have characterized and estimated aquifer properties from electrical sounding data in different geologic environments (<xref ref-type="bibr" rid="R921">Batte <italic>et al.,</italic> 2010</xref>; <xref ref-type="bibr" rid="R939">Majumdar and Das, 2011</xref>; <xref ref-type="bibr" rid="R956">Sikandar and Christen, 2012</xref>; <xref ref-type="bibr" rid="R920">Asfahani, 2012</xref>; <xref ref-type="bibr" rid="R945">Niwas and Celik, 2012</xref>; <xref ref-type="bibr" rid="R947">Nwosu <italic>et., al</italic> 2013</xref>). <xref ref-type="bibr" rid="R958">Soupious <italic>et al.,</italic> (2006)</xref> used vertical electrical sounding (VES) data and Dar-Zarrouk (DZ) parameters and suggested a relationship between transverse resistance and the transmissivity of aquifers in Keritis Basin in Chania (Crete-Greece). In these studies several mathematical equations and correlations were developed to estimate hydraulic aquifer properties from surficial electrical data. However, <xref ref-type="bibr" rid="R952">Sattar <italic>et al.,</italic> (2016)</xref> are of the view that these estimations are area specific and likely to change in different geologic provinces.</p>
<p>A relation between the aquifer intrinsic permeability and formation factor to estimate transmissivity from borehole resistivity measurements was established by <xref ref-type="bibr" rid="R927">Croft (1971)</xref>. However, <xref ref-type="bibr" rid="R966">Worthington (1975)</xref> obtained an inverse relation between the formation factor and inter-granular permeability. <xref ref-type="bibr" rid="R938">Kelly (1977)</xref> established an empirical relation between aquifer electrical resistivity and aquifer hydraulic conductivity and a semi-empirical relation between the aquifer formation factor and hydraulic conductivity. In the present study, an attempt has been made to ascertain the relationship between aquifer and geoelectrical properties in combination with hydro-geochemical information in coastal area of Sindhudurg district, Maharashtra which will improve the characterization of aquifer parameters in the coastal region.</p>
</sec>
<sec id="s2"><title>Study Area And Geological Attributes</title>
<p>The study area is a narrow strip between the Sahaydri ranges and Arabian Sea extending from latitude 16º N to 16.5º N and longitude 73º E to 73.74º E in Sindhudurg district, Maharashtra, India (<xref ref-type="fig" rid="F123">Figure 1</xref>). Different types of rock formations exist in the study area having varied petro-physical properties, imparting different capacities to store and transmit water. Geologically the study area exposes rocks ranging from Archean to Quaternary period. The Archean granites and gneisses are medium to coarse grained and consists of quartz, hornblende, orthoclase biotite and microcline (<xref ref-type="bibr" rid="R925">CGWB, 2014</xref>). Dharwarian meta-sediments (Archean), Kaladgi formation (Precambrian), Deccan Trap lava flows (Upper Cretaceous to Lower Eocene age), Laterite (Pleistocene) and Alluvial deposits (Recent to Sub-Recent) are the water bearing formations in this district (<xref ref-type="bibr" rid="R925">CGWB, 2014</xref>). The Kaladgi formation occurs in limited patches and thus does not form potential aquifer in the area. The Alluviums has limited areal extent found mainly along the coast. As the primary porosity is insignificant in the Deccan trap basalts, secondary porosity due to jointing and fracturing plays an important role in groundwater movement.</p>
<fig id="F123"><label>Figure 1</label><caption><title>Location map of the study area showing the geochemical sampling points and the vertical electrical sounding (VES) points (after GSI, 2000).</title></caption><graphic xlink:href="https://gathacognition.com/uploads/admin/articlefigure/5982754bc600667ee2650366abfdb11b.jpg" mimetype="image" mime-subtype="jpeg"/></fig>
<p>The district falls in humid and high rainfall zone. The annual rainfall ranges from 2542-3938 mm from North to South (<xref ref-type="bibr" rid="R925">CGWB, 2014</xref>). Fluctuations in the temperature with an average annual rainfall of around 3,287 mm are not significant in this coastal region wherein the mean daily maximum temperature is 32.7 ºC and the mean daily minimum temperature is 18.7 ºC, while the relative humidity is greater than 60%. Groundwater level in the study area varies from 2 to 20 m below ground level (<xref ref-type="bibr" rid="R925">CGWB, 2014</xref>).</p>
</sec>
<sec id="s3"><title>Materials And Methods</title>
<p>In this work, 29 Schlumberger VES were considered from the study area (<xref ref-type="fig" rid="F123">Figure 1</xref>) with a maximum current electrode half-spacing (AB/2) of 100 m. Resistivity measurements was carried out using a digital signal-enhancement resistivity meter (IGIS make, Hyderabad). All the 29 VES stations were conducted close to pre-existing wells. A total of 29 water samples (<xref ref-type="fig" rid="F123">Figure 1</xref>), collected from the respective dug wells and boreholes were used for the determination of pore-water resistivity.</p>
<p>The calculated apparent resistivity data were inverted to construct true geological model of the subsurface using IPI2WIN software (<xref ref-type="bibr" rid="R922">Bobachev, 2003</xref>). The aquifer model parameters (layer resistivity and layer thickness) for all 29 VES sites were used for estimating the hydraulic parameters. The resolution of resistivity data interpretation is often hindered due to some geophysical similarities in the behavior of different geomaterials. In view of this, secondary geophysical parameters (\(T_r\), transverse resistance and \(S\), longitudinal conductance) (also known as Dar Zarrouk, (D-Z) parameters) are used to minimize these uncertainties (<xref ref-type="bibr" rid="R940">Maillet, 1947</xref>).</p>
<p>Several relationships between transverse resistance (\(T_r\)), longitudinal conductance (\(S\)), transmissivity and hydraulic conductivity have been established by different workers (<xref ref-type="bibr" rid="R959">Ungemach <italic>et al.,</italic> 1969</xref>; <xref ref-type="bibr" rid="R938">Kelly, 1977</xref>; <xref ref-type="bibr" rid="R941"> Mazáč <italic>et al.,</italic> 1985</xref>; <xref ref-type="bibr" rid="R946">Niwas and Singhal, 1985</xref>; <xref ref-type="bibr" rid="R935">Huntley, 1986</xref>; <xref ref-type="bibr" rid="R942">Mazáč <italic>et al.,</italic> 1988</xref>; <xref ref-type="bibr" rid="R923">Boerner <italic>et al.,</italic> 1996</xref>; <xref ref-type="bibr" rid="R926">Christensen and Sorensen, 1998</xref>; <xref ref-type="bibr" rid="R950">Rubin and Hubbard, 2005</xref>; <xref ref-type="bibr" rid="R958">Soupis <italic>et al.,</italic> 2007</xref>). These relationships were essentially site specific.</p>
<p>In order to acquire quantitative information on groundwater flow and pollutant transport modeling, evaluation of hydraulic properties of any given aquifer system is of prime importance. These aquifer hydraulic properties are obtained either from conventional pumping tests carried out in wells or from laboratory core samples experiments (<xref ref-type="bibr" rid="R958">Soupios <italic>et al.,</italic> 2007</xref>). In the present study, using the Kozeny–Carman–Bear (KCB) equation (<xref ref-type="bibr" rid="R930">Domenico and Schwartz, 1990</xref>), hydraulic conductivity values were estimated. The porosity (\(\phi\)) and other petro physical parameter required in KCB equation was calculated using Archie’s empirical law (<xref ref-type="bibr" rid="R919">Archie, 1942</xref>).</p>
<p>\(\rho_o=a\rho_w\phi^{-m}\) (1)</p>
<p>where, \(\rho_o\), \(\rho_w\), \(a\), \(m\) and \(\phi\) are bulk resistivity, pore-water resistivity, pore geometry factor, cementation factor and fractional porosity, respectively.</p>
<p>Equation 1 is applicable to clay free medium only and thus \(\frac{\rho_o}{​​\rho_w}\) ratio is known as the intrinsic formation factor (<italic>\(F_i\)</italic>). Accordingly, equation 1 could be re-written as (equation 2),</p>
<p>\(\phi=e^{\frac{1}{m}In(a)+\frac{1}{m}In(\frac{1}{F_i})}\) (2)</p>
<p>The coefficients \(a\) and \(m\) is usually determined from core samples for each site under investigation. But, due to unavailability of core samples in the study area, the values for \(a\) and \(m\) reported in published literature was used to obtain porosity values.</p>
<p><xref ref-type="bibr" rid="R967">Worthington (1993)</xref> advocated three different expressions to compute intrinsic formation factor corresponding to the porosity of samples from different sites. A fourth expression is given by <xref ref-type="bibr" rid="R936">Jackson <italic>et al.,</italic> (1978)</xref> and <xref ref-type="bibr" rid="R929">De Lima and Sharma (1990)</xref> where the coefficient \(a\) has the value of 1 while \(m\) varies from 1.3 to 2.5. As mentioned earlier, Archie’s formula (equation (1) and (2)) is applicable only for clay-free, clean, consolidated sediments and therefore any departure from these assumptions from actual field data make the equation invalid. <xref ref-type="bibr" rid="R967">Worthington (1993)</xref> proposed that for unclean, clayey and shaley sands and a mixture of sand/ gravels, some remedial measure for clay conductivity is required and thus in the present study, the coefficient \(a\) has the value of unity while \(m\) is taken as 2.5.</p>
<p>Several researchers have given different models which are basically derived empirically using the notion of parallel conductor (<xref ref-type="bibr" rid="R948">Patnode and Wyllie, 1950</xref>; <xref ref-type="bibr" rid="R965">Winsauer and McCardell, 1953</xref>; <xref ref-type="bibr" rid="R962">Waxman and Smits, 1968</xref>; <xref ref-type="bibr" rid="R954">Sen <italic>et al</italic>., 1988</xref>). In the present study, the Archie’s equation was modified using the Waxman–Smits model (<xref ref-type="bibr" rid="R960">Vinegar and Waxman, 1984</xref>) which relates the apparent formation factor (\(F_a\)) (which is the ratio of bulk resistivity to pore-water resistivity) and intrinsic formation factor (<italic>\(F_i\))</italic>, after taking into account the shale effects. According to <xref ref-type="bibr" rid="R967">Worthington (1993)</xref>,</p>
<p>\(F_a=F_i(1+BQ_V\rho_w)^{-1}\) (3)</p>
<p>where, \(BQ_V\) term is related to the effects of surface conduction due to clay particles. In case of surface conduction effects are non-existent, the apparent formation factor (\(F_a\)) is equal to the intrinsic formation factor (<italic>\(F_i\)</italic>). Rearranging the terms in equation 3, we obtain,</p>
<p>\(\frac{1}{​​F_a}=\frac{1}{​​F_i}+(\frac {BQ_V}{F_i})\rho_w\) (4)</p>
<p>Consequently, plotting the pore-water resistivity ( \(\rho_w\) ) as a function of \(\frac{1}{​​F_a}\) enables us to get the corrected \(\frac{1}{​​F_i}\) values. The relation theoretically results in a straight line and \((\frac {BQ_V}{F_i})\) is denoted by slope (<xref ref-type="bibr" rid="R928">Das <italic>et al.,</italic> 2016</xref>). The value of the corrected formation factor thus obtained will subsequently facilitate us to estimate porosity via equation 2. The above approach is followed by using bulk resistivity \(\rho_o\) obtained from the one-dimensional (1D) resistivity inversion coupled with pore-water resistivities measured from wells near VES stations. However, some uncertainty prevails here due to fact that a few of the wells are at some distance away from the corresponding VES points.</p>
<p><xref ref-type="table" rid="T72">Table 1</xref> gives the resistivity values obtained from 1D inversion and the calculated apparent formation factors. By applying least square best fit linear approach of the individual groups of the dataset between \(\frac{1}{​​F_a}\) and pore-water resistivity (\(\rho_w\)), the intrinsic formation factor is obtained which ranges from 0.000318 to 0.0389 (<xref ref-type="fig" rid="F123">Table 1</xref>). The porosity values can now be estimated by substituting the \(\frac{1}{​​F_i}\) values, and the \(a\) and \(m\) values are taken as 1 and 2.5, respectively in equation 2.</p>
<table-wrap id="T72"><label>Table 1</label><caption><title>Evaluation of formation factors and other aquifer parameters obtained from geophysical data.</title></caption><table frame="hsides" rules="groups">
<tbody>
<tr><td><bold>1</bold></td><td><bold>2</bold></td><td><bold>3</bold></td><td><bold>4</bold></td><td><bold>5</bold></td><td><bold>6</bold></td><td><bold>7</bold></td><td><bold>8</bold></td><td><bold>9</bold></td><td><bold>10</bold></td><td><bold>11</bold></td><td><bold>12</bold></td><td><bold>13</bold></td></tr>
<tr><td>1</td><td>1</td><td>31.54</td><td>1232</td><td>59.2</td><td>39.07</td><td>0.026</td><td>0.0008</td><td>5.771</td><td>0.727</td><td>43.052</td><td>72909.64</td><td>1.01</td></tr>
<tr><td>4</td><td>2</td><td>18.61</td><td>718</td><td>9.66</td><td>38.59</td><td>0.026</td><td>0.0014</td><td>7.219</td><td>1.468</td><td>14.182</td><td>23650.84</td><td>1.74</td></tr>
<tr><td>5</td><td>3</td><td>18.39</td><td>56</td><td>8.34</td><td>3.04</td><td>0.328</td><td>0.0179</td><td>20.01</td><td>42.04</td><td>350.594</td><td>729.82</td><td>1.17</td></tr>
<tr><td>6</td><td>4</td><td>29.99</td><td>234</td><td>14.1</td><td>7.80</td><td>0.128</td><td>0.0043</td><td>11.31</td><td>6.176</td><td>87.087</td><td>4345.22</td><td>1.08</td></tr>
<tr><td>8</td><td>5</td><td>53.71</td><td>330</td><td>8.12</td><td>6.14</td><td>0.163</td><td>0.0030</td><td>9.791</td><td>3.876</td><td>31.474</td><td>16631.3</td><td>2.1</td></tr>
<tr><td>9</td><td>6</td><td>55.99</td><td>291</td><td>54.6</td><td>5.20</td><td>0.192</td><td>0.0034</td><td>10.29</td><td>4.555</td><td>248.694</td><td>59333.28</td><td>1.75</td></tr>
<tr><td>10</td><td>7</td><td>57.41</td><td>7584</td><td>17.7</td><td>132.1</td><td>0.008</td><td>0.0001</td><td>2.790</td><td>0.077</td><td>1.367</td><td>117641.8</td><td>1.55</td></tr>
<tr><td>11</td><td>8</td><td>24.99</td><td>329</td><td>26.1</td><td>13.16</td><td>0.076</td><td>0.0030</td><td>9.791</td><td>3.876</td><td>101.165</td><td>143277.6</td><td>3.55</td></tr>
<tr><td>12</td><td>9</td><td>19.43</td><td>814</td><td>23.6</td><td>41.89</td><td>0.024</td><td>0.0012</td><td>6.787</td><td>1.209</td><td>28.531</td><td>19117.44</td><td>1.07</td></tr>
<tr><td>13</td><td>10</td><td>53.45</td><td>5249</td><td>6.98</td><td>98.21</td><td>0.010</td><td>0.0002</td><td>3.247</td><td>0.123</td><td>0.858</td><td>56219.69</td><td>1.41</td></tr>
<tr><td>14</td><td>11</td><td>19.34</td><td>15</td><td>40</td><td>0.775</td><td>1.29</td><td>0.066</td><td>33.7</td><td>293</td><td>11722.3</td><td>4378</td><td>1.16</td></tr>
<tr><td>15</td><td>12</td><td>11.43</td><td>25.7</td><td>32.7</td><td>2.25</td><td>0.445</td><td>0.0389</td><td>27.29</td><td>129.1</td><td>4222.99</td><td>7249.01</td><td>2.32</td></tr>
<tr><td>16</td><td>13</td><td>40.70</td><td>4901</td><td>15.7</td><td>120.4</td><td>0.008</td><td>0.0002</td><td>3.341</td><td>0.134</td><td>2.105</td><td>71877.67</td><td>1.12</td></tr>
<tr><td>17</td><td>14</td><td>19.33</td><td>7018</td><td>8.24</td><td>363.1</td><td>0.003</td><td>0.0001</td><td>2.890</td><td>0.086</td><td>0.709</td><td>47587.86</td><td>1.38</td></tr>
<tr><td>18</td><td>15</td><td>29.55</td><td>1326</td><td>23.2</td><td>44.87</td><td>0.022</td><td>0.0008</td><td>5.636</td><td>0.675</td><td>15.670</td><td>29009.36</td><td>1.58</td></tr>
<tr><td>19</td><td>16</td><td>24.89</td><td>217</td><td>22.8</td><td>8.72</td><td>0.115</td><td>0.0046</td><td>11.62</td><td>6.744</td><td>153.762</td><td>6882.21</td><td>1.12</td></tr>
<tr><td>21</td><td>17</td><td>40.54</td><td>668</td><td>7.77</td><td>16.48</td><td>0.061</td><td>0.0015</td><td>7.421</td><td>1.602</td><td>12.446</td><td>14343.5</td><td>1.52</td></tr>
<tr><td>22</td><td>18</td><td>30.77</td><td>87.4</td><td>57.4</td><td>2.84</td><td>0.352</td><td>0.0114</td><td>16.70</td><td>22.56</td><td>1294.99</td><td>53247.31</td><td>2.46</td></tr>
<tr><td>23</td><td>19</td><td>18.27</td><td>6424</td><td>7.01</td><td>351.6</td><td>0.003</td><td>0.0016</td><td>7.538</td><td>1.683</td><td>11.800</td><td>21178.16</td><td>2.11</td></tr>
<tr><td>24</td><td>20</td><td>16.05</td><td>70.3</td><td>2.82</td><td>4.38</td><td>0.228</td><td>0.0142</td><td>18.24</td><td>30.48</td><td>85.942</td><td>771.59</td><td>1.8</td></tr>
<tr><td>26</td><td>21</td><td>31.31</td><td>31381</td><td>25.3</td><td>1002</td><td>0.001</td><td>0.0000</td><td>1.588</td><td>0.014</td><td>0.352</td><td>729546.3</td><td>1.04</td></tr>
<tr><td>27</td><td>22</td><td>41.15</td><td>1470</td><td>19.3</td><td>35.72</td><td>0.028</td><td>0.0007</td><td>5.408</td><td>0.594</td><td>11.460</td><td>22878.05</td><td>1.07</td></tr>
<tr><td>28</td><td>23</td><td>22.72</td><td>109</td><td>23.8</td><td>4.80</td><td>0.208</td><td>0.0092</td><td>15.33</td><td>16.89</td><td>401.784</td><td>4733.19</td><td>1.31</td></tr>
<tr><td>29</td><td>24</td><td>41.89</td><td>444</td><td>41.6</td><td>10.60</td><td>0.094</td><td>0.0023</td><td>8.804</td><td>2.757</td><td>114.698</td><td>64523.55</td><td>1.75</td></tr>
<tr><td>30</td><td>25</td><td>40.65</td><td>10927</td><td>10.2</td><td>268.8</td><td>0.004</td><td>0.0001</td><td>2.429</td><td>0.051</td><td>0.516</td><td>115678.1</td><td>1.00</td></tr>
<tr><td>31</td><td>26</td><td>13.48</td><td>3342</td><td>0.662</td><td>247.9</td><td>0.004</td><td>0.0003</td><td>3.893</td><td>0.215</td><td>0.142</td><td>586.35</td><td>2.74</td></tr>
<tr><td>32</td><td>27</td><td>0.96</td><td>221</td><td>47.5</td><td>230.3</td><td>0.004</td><td>0.0045</td><td>11.55</td><td>6.553</td><td>311.282</td><td>13049.52</td><td>1.13</td></tr>
<tr><td>33</td><td>28</td><td>823.72</td><td>360</td><td>43.5</td><td>0.44</td><td>2.288</td><td>0.0028</td><td>9.525</td><td>3.547</td><td>154.298</td><td>88581.07</td><td>2.13</td></tr>
<tr><td>34</td><td>29</td><td>187.58</td><td>204</td><td>36.7</td><td>1.09</td><td>0.920</td><td>0.0049</td><td>11.92</td><td>7.324</td><td>268.802</td><td>12182.95</td><td>1.21</td></tr>
<tr><td colspan="13">1. Well Number; 2. VES point; 3. Pore-water resistivity (Ω-m); 4. Bulk resistivity (Ω-m); 5. H (m); 6. F<sub>a</sub>; 7. 1/F<sub>a</sub>; 8.1/F<sub>i</sub>; 9. Porosity (%); 10. Hydraulic Conductivity (m/d); 11. Transmissivity (m<sup>2</sup>/d); 12. Transverse Resistance (Ω -m<sup>2</sup>); 13. Electrical Anisotropy (λ).</td></tr>
<tr><td colspan="13"></td></tr>
</tbody>
</table>
</table-wrap>
<p>In order to determine the hydraulic conductivity (\(k\)), KCB equation 5 (<xref ref-type="bibr" rid="R958">Soupis <italic>et al.,</italic> 2007</xref>) was used as,</p>
<p>\(k =(\frac{\delta_wg}{\mu})\cdot(\frac{d^2}{180})\cdot(\frac{\phi^3}{{(1-\phi})^2})\) (5)</p>
<p>where, \(d\) is the grain size (0.01 cm) (<xref ref-type="bibr" rid="R958">Soupis <italic>et al., </italic>2007</xref>), \(\delta_w\) fluid density (1000 kg/m<sup>3</sup>), \(\mu\) and \(g\) are dynamic viscosity of the fluid (0.0014 kg/ms) and acceleration due to gravity (<xref ref-type="bibr" rid="R931">Fetter, 1994</xref>), respectively.</p>
<p>The secondary geophysical parameters of significance in this study are longitudinal conductance \(S\), transverse resistance \(T_r\) and electrical anisotropy \(\lambda\) which are given after (<xref ref-type="bibr" rid="R968">Zohdy, 1974</xref>) for \(n\)-layer as,</p>
<p>Longitudinal conductance,   \(S=\sum_{i=1}^{n} (\frac{h_i}{\rho_i})\) (6)</p>
<p>Transverse resistance, \(T_r=\sum_{i=1}^{n} ({h_i}{\rho_i})\) (7)</p>
<p>where, \(h_i\) is the saturated thickness of each layer, \(\rho_i\) is the true resistivity of each layer.</p>
<p>Coefficient of anisotropy \(\lambda = \sqrt{( \frac {\rho_t}{\rho_l}) }\) (8)</p>
<p>where, \(\rho_t\) and \(\rho_l\)  are the average transverse resistivity and average longitudinal resistivity, respectively.</p>
<p>The rate of flow of the aquifer is called the transmissivity (\(T\)), which can be calculated by the following equation</p>
<p>\(T=k*h\) (9)</p>
<p>where, \(k\) is hydraulic conductivity of the aquifer which is obtained from equation 5 and \(h\) is thickness of the aquifer derived from the 1D resistivity values of the VES points. These enable us to derive a relation between transverse resistivity and transmissivity, to be discussed later. Also the relation between porosity and electrical anisotropy is obtained in order to understand the functional corresponding relationship.</p>
</sec>
<sec id="s4"><title>Results And Discussion</title>
<p>As mentioned earlier, the correlation between pore-water resistivity ( \(\rho_w\) ) and inverted formation factor ( \(\frac{1}{F_a}\) ) is obtained in order to calculate the intrinsic formation factor ( \(F_i\) ) (<xref ref-type="fig" rid="F125">Figure 2</xref>). This revealed a straight</p>
<fig id="F125"><label>Figure 2</label><caption><title>Determination of the intrinsic formation factor</title></caption><graphic xlink:href="https://gathacognition.com/uploads/admin/articlefigure/3f1a0a3089002a51538c3cd22fe8156e.jpg" mimetype="image" mime-subtype="jpeg"/></fig>
<p>line with slope 0.004 and intercept value of -0.044 and giving the coefficient of determination of 0.583. The correlation plot suggests that as <italic>ρ<sub>w </sub></italic>increases, the formation factor (\(F_a\)) decreases which satisfy the Archie’s equation.</p>
<p>In the present work, the spatial variation of aquifer parameters were determined using the ordinary kriging technique, which is a linear stochastic method using semi-variogram model fitting schemes so as to estimate values at unknown sites using the values at known sites (<xref ref-type="bibr" rid="R928">Das <italic>et al.,</italic> 2016</xref>).</p>
<sec id="s4-1"><title>4.1 Spatial Distribution of Aquifer Thickness</title>
<p><xref ref-type="fig" rid="F126">Figure 3</xref> represents the spatial variability of the aquifer thickness, which is extracted from the VES location (<xref ref-type="table" rid="T72">Table 1</xref>). The aquifer thickness ranges from 0.67 to 59 m in the study area. The low aquifer thickness below 5 m was observed at locations 24 and 31. Higher aquifer thickness greater than 30 m were seen along the coastal sites 14, 15, 32 and 33, central region (9, 22 and 29) and at site number 1 to the East, due to undulating topography. Thickness of the aquifer plays a very important role in understanding the hydraulic parameters of the study area. Moderately thick aquifers seen mainly in the Northwest and central part of the study area may represent productive aquifer zones. In the basaltic terrain, groundwater occurs under unconfined conditions in the phreatic zone up to a depth of 15-20 m in the weathered zone, fractures and joints in the massive unit and weathered/fractured vesicular units.</p>
<fig id="F126"><label>Figure 3</label><caption><title>Spatial variability map of aquifer thickness (H).</title></caption><graphic xlink:href="https://gathacognition.com/uploads/admin/articlefigure/b839ee1aa25598f07b3ef2e0d4d9343a.jpg" mimetype="image" mime-subtype="jpeg"/></fig>
</sec>
<sec id="s4-2"><title>4.2 Spatial distribution of porosity</title>
<p>The spatial distribution map of the porosity is shown in <xref ref-type="fig" rid="F127">Figure 4</xref>. Porosity is a very important parameter in the aquifer characterization and groundwater management. Evidently the productivity of an aquifer depends on the geological characteristics of the lithological units and porosity. The aquifer porosity in the study area ranges from 1.5 to 33% (<xref ref-type="table" rid="T72">Table 1</xref>). Generally the porosity values reported earlier from the southern part of the study area ranges up to about 30% (<xref ref-type="bibr" rid="R928">Das <italic>et al </italic>2016</xref>). Porosity values &gt;20% are observed at locations 5, 14, 15, 22, 24 and 28. Very high porosity values (&gt;27%) are observed at south-western part at wells 14 and 15, since this part of the coastal tract comprises of alluvium formation of fine grain and un-lithified sediments (<xref ref-type="fig" rid="F127">Figure 4</xref>), resulting in high porosity content.</p>
<fig id="F127"><label>Figure 4</label><caption><title>Spatial variability map of porosity.</title></caption><graphic xlink:href="https://gathacognition.com/uploads/admin/articlefigure/3bd9d64f39209d68ecf8cc6e0c07948c.jpg" mimetype="image" mime-subtype="jpeg"/></fig>
</sec>
<sec id="s4-3"><title>4.3 Spatial Distribution of Hydraulic Conductivity</title>
<p>The spatial distribution map of the hydraulic conductivity (<xref ref-type="fig" rid="F128">Figure 5</xref>) is a vital parameter of aquifer systems as it strongly affects fluid flow by creating flow barriers or preferential flow paths. The estimated hydraulic conductivity (\(k\) is shown in <xref ref-type="table" rid="T72">Table 1</xref>, which ranges from 0.014 to 293 m/day. High \(k\) values (&gt;100 m/day) are observed in the coastal part at sites 14 and 15. This part also revealed high porosity values indicating that it is underlain by good aquifer materials and thus making the area a good prospect for groundwater. The \(k\) map further suggests moderately high values in the Southern, Eastern and Central parts of the study area, which are characterized by high porosity. This suggests that cracks and inter-connected pores play a major role in the permeability to determine the conductivity of fractured rocks (<xref ref-type="bibr" rid="R932">Francis, 1981</xref>; <xref ref-type="bibr" rid="R953">Schwartz and Zhang, 2004</xref>).</p>
<fig id="F128"><label>Figure 5</label><caption><title>Spatial variability map of hydraulic conductivity.</title></caption><graphic xlink:href="https://gathacognition.com/uploads/admin/articlefigure/4578c5a416f06f200fd8f15523f62e8b.jpg" mimetype="image" mime-subtype="jpeg"/></fig>
<p>The correlation between bulk resistivity and hydraulic conductivity is usually considered for clean saturated sediments, whose natural fluid characteristics are constant (<xref ref-type="bibr" rid="R934">Henriet, 1975</xref>). The correlation plot (<xref ref-type="fig" rid="F129">Figure 6</xref>) reveals a negative relation between these two parameters suggesting that the hydraulic conductivity exponentially decreases with increasing bulk resistivity due granitic gneiss and lateritic formations (<xref ref-type="bibr" rid="R928">Das <italic>et al.,</italic> 2016</xref>). Rock properties are influenced by the permeability including particle size, its packing and distribution and degree of lithification. In the present study, the increase in hydraulic conductivity with decreasing bulk resistivity is attributable to the better inter-connectivity of fracture network in crystalline hard rock.</p>
<fig id="F129"><label>Figure 6</label><caption><title>Correlation plot between bulk resistivity and hydraulic conductivity.</title></caption><graphic xlink:href="https://gathacognition.com/uploads/admin/articlefigure/97502befd01127dcb38a2be643352d85.jpg" mimetype="image" mime-subtype="jpeg"/></fig>
</sec>
<sec id="s4-4"><title>4.4 Spatial Distribution of Transmissivity</title>
<p>Transmissivity (\(T\)) is defined as the rate of flow under a unit hydraulic gradient through a unit width of aquifer of given saturated thickness. It is the most important parameter in hydrogeological environment because the higher transmissivity, more productive is the aquifer. In the present study, the <italic>T </italic>value ranges from 0.142 to 11722 m<sup>2</sup>/day (<xref ref-type="table" rid="T72">Table 1</xref>). Higher values are observed at station 14 (11722.4 m<sup>2</sup>/day) and station 15 (4222.9 m<sup>2</sup>/day) (<xref ref-type="fig" rid="F130">Figure 7</xref>). Station 22 in the central part of the study area shows \(T\) value of 1294.9 m<sup>2</sup>/day. These three sampling points are not considered in interpretation as the very high <italic>T</italic> value tends to mask the effects of other features in its vicinity. However, it is marked on the map (<xref ref-type="fig" rid="F130">Figure 7</xref>) and the \(T\) values are given in parenthesis. These three stations have more aquifer thickness and hydraulic conductivity, thereby leading to higher transmissivity. Pumping test results of aquifer parameters from the study area suggests that the transmissivity ranges from 5.6 to 375 m<sup>2</sup>/day (<xref ref-type="bibr" rid="R925">CGWB, 2014</xref>). It can be observed from the present study that apart from samples 14, 15 and 22 all other samples are comparable with the transmissivity values given by <xref ref-type="bibr" rid="R925">CGWB (2014)</xref>. Also the spatial variation map of transmissivity (<xref ref-type="fig" rid="F130">Figure 7</xref>) reveals a positive correspondence with hydraulic conductivity almost over the entire study area in general and at Western part in particular.</p>
<fig id="F130"><label>Figure 7</label><caption><title>Spatial variability map of transmissivity (T).</title></caption><graphic xlink:href="https://gathacognition.com/uploads/admin/articlefigure/f6e9b8570f15a22075fa2ed131864380.jpg" mimetype="image" mime-subtype="jpeg"/></fig>
</sec>
<sec id="s4-5"><title>4.5 Correlation between Transmissivity and Transverse Resistivity</title>
<p>As mentioned earlier, transmissivity is an indication of the ability of a layer of known hydraulic conductivity to transmit fluids through its entire thickness. It has been advocated that the transmissivity of an aquifer is directly proportional to its transverse resistance (<xref ref-type="bibr" rid="R934">Henriet, 1975</xref>; <xref ref-type="bibr" rid="R961">Ward, 1990</xref>). In order to check the accuracy of the computed hydraulic conductivity values determined from the resistivity values, an attempt is made to obtain a relationship between transmissivity and transverse</p>
<p>resistance. The transverse resistance value ranges from 586 to &gt;700000 Ω -m<sup>2</sup> (<xref ref-type="table" rid="T72">Table 1</xref>). High transverse resistance values are usually associated with zones of high transmissivity and hence highly permeable to fluid movement. A positive relation is obtained between transmissivity and transverse resistance and the best fit regression line is shown in <xref ref-type="fig" rid="F131">Figure 8</xref>. This suggests that the prospective aquifer zones in the study area increases with increasing transverse resistance. These are presumably due to changes in hydraulic conductivities and electrical anisotropy, in addition to the disparity in lithology, mineralogy, grain size, size and shape of the pores and pore channels (<xref ref-type="bibr" rid="R951">Salem, 1999</xref>).</p>
<fig id="F131"><label>Figure 8</label><caption><title>Relation between Transverse Resistance, TR (Ω -m2) and Transmissivity, T (m2/day).</title></caption><graphic xlink:href="https://gathacognition.com/uploads/admin/articlefigure/ed94f6117f49ccc7941557d1dcfcac44.jpg" mimetype="image" mime-subtype="jpeg"/></fig>
</sec>
<sec id="s4-6"><title>4.6 Correlation between Electrical Anisotropy and Porosity</title>
<p>Fractures in rocks are important pathways for groundwater flow and contaminant migration. Groundwater flow through a fracture network is strongly influenced by anisotropy resulting from the geometry of the fractures (<xref ref-type="bibr" rid="R957">Slater <italic>et al.,</italic> 2006</xref>), since both current flow and groundwater are channeled through fractures in the rock. It is reported by <xref ref-type="bibr" rid="R968">Zohdy (1974)</xref> that the coefficient of anisotropy (λ) is generally 1 and seldom exceeds 2 in most of the geological conditions. <xref ref-type="bibr" rid="R937">Keller and Frischknecht (1966)</xref> are of the view that as the hardness and compaction of rocks increases, \(\lambda\) also tends to increase, which are thus associated with low porosity and permeability.</p>
<p>Electrical anisotropy in the study area varies from 1-3.55 (<xref ref-type="table" rid="T72">Table 1</xref>). The coefficient of anisotropy is not uniform in all directions and is observed to increase from SW to NE and also from SE to NW (<xref ref-type="fig" rid="F132">Figure 9</xref>), thus playing a major role in fracturing. More fracturing towards the NE an SW directions suggest relatively more prospective groundwater zone. Resistivity of subsurface rocks affects both the electrical anisotropy and porosity. Porosity critically depends upon the existence of a petrophysical relationship between geoelectrical properties in an area. An analogy drawn between both these parameters (<xref ref-type="fig" rid="F133">Figure 10</xref>) suggests that about 80% of the sampling sites concentrated within λ values 1-2 reveal higher porosity. This implies that the study area portrays differing extent of saturation zones within the lateritic and basaltic rock formation.</p>
<fig id="F132"><label>Figure 9</label><caption><title>Spatial variability map of electrical anisotropy (λ).</title></caption><graphic xlink:href="https://gathacognition.com/uploads/admin/articlefigure/682d01ae74c29eb26c225f5072e7a7ed.jpg" mimetype="image" mime-subtype="jpeg"/></fig>
<fig id="F133"><label>Figure 10</label><caption><title>Plot of electrical anisotropy (λ) and porosity.</title></caption><graphic xlink:href="https://gathacognition.com/uploads/admin/articlefigure/b4f5dc04526de00d8446ca479c5ea537.jpg" mimetype="image" mime-subtype="jpeg"/></fig>
</sec>
</sec>
<sec id="s5"><title>Conclusions</title>
<p>An integrated method is presented to estimate the aquifer parameters by using vertical electrical sounding (VES) and hydrochemical data of the coastal region of Sindhudurg district, Western Maharashtra, India. This is very cost effective and quick when pumping test data of the area is unavailable. The relation between bulk resistivity and hydraulic conductivity is established by using VES inverted data and hydrochemical sample analysis. Further, spatial variation of aquifer parameters like transmissivity, hydraulic conductivity, aquifer thickness and porosity was evaluated and contoured using ordinary kriging scheme.</p>
<p>The transmissivity values are vary between 0.142 and 11722 m<sup>2</sup>/day, which can be attributed to the subsurface inhomogeneity of the sandy silt and lateritic formations in the coastal part of the study area. The high values of transmissivity could be due to the presence of fractured medium saturated with water, suggesting high potential within the water-bearing formation. The <italic>T</italic> values observed here are corroborating well with the values obtained from pumping test data of <xref ref-type="bibr" rid="R925">CGWB (2014)</xref>. A positive linear relationship has been obtained between transmissivity and transverse resistance which suggests high permeability formations. The calculated hydraulic conductivity reveals high values (&gt;100 m/day) near the coastal part of the study area. This is due to the increase in sandy silt thickness and also due to high porosity values because the grain size is very fine. The high porosity also advocates that the geological medium could be fractured and indicative of high potential water-bearing formations. The regions of high porosity also corroborates with the regions of electrical anisotropy (between 1 and 2). This suggests the subsurface in homogeniety is due to layers with different resistivity values and also due to fracturing, metamorphism and disseminated ore grains in the rocks.</p>
<p>From the foregoing it can be surmised that geoelectrical sounding technique can be successfully integrated with hydro geochemical parameters for evaluating the hydraulic parameters of the aquifer. This scheme is very suitable where pumping tests data is not available and therefore is cost effective and can significantly reduce the amount of test drilling sites. Such studies can thus be implemented for detailed investigation so as to provide rapid complementary data for the assessment of groundwater potential zones especially in hard-rock terrain of the country where resources are meager.</p>
</sec>
</body>
<back>
<ack>
<title>Acknowledgements</title>
<p>The authors are indebted to Dr. D.S. Ramesh, Director, <ext-link ext-link-type="uri" xlink:href="http://www.iigm.res.in/">IIG</ext-link> for the support and kind permission to publish this work. The first author Suneetha Naidu is thankful to IIG SRF fellowship in which this work related to her Ph.D. Thanks are due to Shri. B. I. Panchal for drafting the figures.</p>
</ack>
<glossary>
<title>Abbreviations</title>
<p><bold>CGWB</bold>: Central Ground Water Board; <bold>GSI</bold>: Geological Survey of India; <bold>KCB</bold>: Kozeny–Carman–Bear; <bold>VES</bold>: Vertical Electrical Sounding (VES); <bold>DZ</bold>: Dar-Zarrouk.</p>
</glossary>
<fn-group>
<fn fn-type="coi-statement">
<p>The authors declare no conflict of interest.</p>
</fn>
</fn-group>
<ref-list>
<title>References</title>
<ref id="R919"><mixed-citation>Archie, G. E., 1942. The electrical resistivity log as an aid in determining some reservoir characteristics. <italic>American Institute of Mineral and Metal Engineering, Technical Publication, </italic>1422, Petroleum Technology, 8-13.</mixed-citation></ref>
<ref id="R920"><mixed-citation>Asfahani, J., 2012. Quaternary aquifer transmissivity derived from vertical electrical sounding measurements in the Semi-Arid Khanasser Valley region, Syria. <italic>Acta Geophysical,</italic> 60(4), 1143-1158. <pub-id pub-id-type="doi">10.2478/s11600-012-0016-x</pub-id></mixed-citation></ref>
<ref id="R921"><mixed-citation>Batte, A. G., Barifaijo, E., Kiberu, J. M., Kawule, W., Muwanga, A., Owor, M. and Kisekulo, J., 2010. Correlation of geoelectric data with aquifer parameters to delineate the groundwater potential of hard rock terrain in Central Uganda. <italic>Pure appl. Geophys.,</italic> 167(12) 1549-1559. <pub-id pub-id-type="doi">10.1007/s00024-010-0109-x</pub-id></mixed-citation></ref>
<ref id="R922"><mixed-citation>Bobachev, C., 2002. IPI2Win: A windows software for an automatic interpretation of resistivity sounding data, Ph. D. Thesis, Moscow State University.</mixed-citation></ref>
<ref id="R923"><mixed-citation>Boerner, F. D., Schopper, J. R. and Wller, A., 1996. Evaluation of transport and storage properties in the soil and groundwater zone from induced polarisation measurements. <italic>Geophysics,</italic> 44, 583-601. <pub-id pub-id-type="doi">10.1111/j.1365-2478.1996.tb00167.x</pub-id></mixed-citation></ref>
<ref id="R924"><mixed-citation>Cassidy, J., Comte, J., Nitsche, C., Wilson, R., Flynn, U. and Ofterdinger, R., 2014. Combining multi-scale geophysical techniques for robust hydro-structural characterisation in catchments underlain by hard rock in post-glacial region. <italic>J. Hydrol.,</italic> 517, 715-731. <pub-id pub-id-type="doi">10.1016/j.jhydrol.2014.06.004</pub-id></mixed-citation></ref>
<ref id="R925"><mixed-citation>CGWB [Central Ground Water Board], 2014. Groundwater information Sindhudurg district Maharashtra. <italic>Technical Report for Ministry of Water Resources, Government of India,</italic> 1835/DB/2014, 16.</mixed-citation></ref>
<ref id="R926"><mixed-citation>Christensen, N. B. and Sorensen, K. I., 1998. Surface and borehole electric and electromagnetic methods for hydrogeological investigations. <italic>European Jour. Environ. Engg. Geophys.,</italic> 31, 75-90.</mixed-citation></ref>
<ref id="R927"><mixed-citation>Croft, M. G., 1971. Method of calculating permeability from electric log. <italic>U.S. Geological Survey Professional,</italic> 750, 265-269.</mixed-citation></ref>
<ref id="R928"><mixed-citation>Das, A., Maiti, S., Suneetha, N. and Gupta, G., 2016. Estimation of spatial variability of aquifer parameters from geophysical methods: A case study of Sindhudurg district, Maharashtra, India. <italic>Stoch. Environ. Res. Risk Assess.,</italic> 31, 1709-1726. <pub-id pub-id-type="doi">10.1007/s00477-016-1317-4</pub-id></mixed-citation></ref>
<ref id="R929"><mixed-citation>De Lima, O. A. L. and Sharma, M. M., 1990. A grain conductivity approach to shaly sand. <italic>Geophysics,</italic> 50, 1347-1356. <pub-id pub-id-type="doi">10.1190/1.1442782</pub-id></mixed-citation></ref>
<ref id="R930"><mixed-citation>Domenico, P. A. and Schwartz, F. W., 1990. <italic>Physical and Chemical Hydrogeology,</italic> Wiley, New York, 324.</mixed-citation></ref>
<ref id="R931"><mixed-citation>Fetter, C. W., 1994. <italic>Applied Hydrogeology,</italic> 3rd edn., Prentice-Hall, New Jersey, 600.</mixed-citation></ref>
<ref id="R932"><mixed-citation>Francis, R. M., 1981. Hydro geological properties of a fractured porous aquifer, Winter River Basin, Prince Edward Island. Unpublished M.Sc. Thesis, University of Waterloo.</mixed-citation></ref>
<ref id="R933"><mixed-citation>GSI [Geological Survey of India], 2000. Seismotectonic atlas of India and its environs. <italic>Geological Survey of India publication,</italic> 87.</mixed-citation></ref>
<ref id="R934"><mixed-citation>Henriet, J. P., 1975. Direct applications of the Dar Zarrouk parameters in ground water surveys. <italic>Geophys. Prospect.,</italic> 24, 344-353. <pub-id pub-id-type="doi">10.1111/j.1365-2478.1976.tb00931.x</pub-id></mixed-citation></ref>
<ref id="R935"><mixed-citation>Huntley, D., 1986. Relations between permeability and electrical resistivity in granular aquifers. <italic>Ground Water, </italic>24(4), 466-474. <pub-id pub-id-type="doi">10.1111/j.1745-6584.1986.tb01025.x</pub-id></mixed-citation></ref>
<ref id="R936"><mixed-citation>Jackson, P. D., Taylor-Smith, D. and Stanford, P. N., 1978. Resistivity-porosity-particles shape relationships for marine sands. <italic>Geophysics,</italic> 43, 1250-1268. <pub-id pub-id-type="doi">10.1190/1.1440891</pub-id></mixed-citation></ref>
<ref id="R937"><mixed-citation>Keller, G. V. and Frischknecht, F. C., 1966. <italic>Electrical Methods in Geophysical Prospecting. </italic>1st edn., Pregamon Press Inc.</mixed-citation></ref>
<ref id="R938"><mixed-citation>Kelly, W., 1977. Geoelectric sounding for estimating aquifer hydraulic conductivity. <italic>Ground Water,</italic> 15(6), 420-425. <pub-id pub-id-type="doi">10.1111/j.1745-6584.1977.tb03189.x</pub-id></mixed-citation></ref>
<ref id="R939"><mixed-citation>Majumdar, R. K. and Das, D., 2011. Hydrological characterization and estimation of aquifer properties from electrical sounding data in Sagar Island region, South 24 Parganas, West Bengal, India. <italic>Asian J. Earth Sci.,</italic> 4(2), 60-74. <pub-id pub-id-type="doi">10.3923/ajes.2011.60.74</pub-id></mixed-citation></ref>
<ref id="R940"><mixed-citation>Maillet, R., 1947. The fundamental equation of electrical prospecting aquifer properties. <italic>Ground Water,</italic> 12, 529-556. <pub-id pub-id-type="doi">10.1190/1.1437342</pub-id></mixed-citation></ref>
<ref id="R941"><mixed-citation>Mazáč, O., Kelly, W. E. and Landa, I., 1985. A hydrogeophysical model for relations between electrical and hydraulic properties of aquifers. <italic>J. Hydrol.,</italic> 79(1-2), 1-19. <pub-id pub-id-type="doi">10.1016/0022-1694(85)90178-7</pub-id></mixed-citation></ref>
<ref id="R942"><mixed-citation>Mazáč, O., Cislerova, M. and Vogel, T., 1988. Application of geophysical methods in describing spatial variability of saturated hydraulic conductivity in the zone of aeration. <italic>J. Hydrol.,</italic> 103, 117-126. <pub-id pub-id-type="doi">10.1016/0022-1694(88)90009-1</pub-id></mixed-citation></ref>
<ref id="R944"><mixed-citation>Niwas, S. and de Lima, O. A., 2003. Aquifer parameter estimation from surface resistivity data. <italic>Ground Water,</italic> 41(1), 94-99. <pub-id pub-id-type="doi">10.1111/j.1745-6584.2003.tb02572.x</pub-id></mixed-citation></ref>
<ref id="R945"><mixed-citation>Niwas, S. and Celik, M., 2012. Equation estimation of porosity and hydraulic conductivity of Ruhrtal aquifer in Germany using near surface geophysics. <italic>J. Appl. Geophys.,</italic> 84, 77-85. <pub-id pub-id-type="doi">10.1016/j.jappgeo.2012.06.001</pub-id></mixed-citation></ref>
<ref id="R946"><mixed-citation>Niwas, S. and Singhal, D. C., 1985. Aquifer transmissivity of porous media from resistivity data. <italic>J. Hydrol.,</italic> 82, 143-153. <pub-id pub-id-type="doi">10.1016/0022-1694(85)90050-2</pub-id></mixed-citation></ref>
<ref id="R947"><mixed-citation>Nwosu, L. I., Nwankwo, C. N. and Ekine, A. S., 2013. Geoelectric investigation of the hydraulic properties of the aquiferous zones for evaluation of groundwater potentials in the complex geological area of Imo State, Nigeria. <italic>Asian J. Earth Sci.,</italic> 6, 1-15. <pub-id pub-id-type="doi">10.3923/ajes.2013.1.15</pub-id></mixed-citation></ref>
<ref id="R948"><mixed-citation>Patnode, W. H. and Wyllie, M. R. J., 1950. The presence of conductive solids in reservoir rocks as factor in electric log interpretation. <italic>Pet. Trans. Am. Inst. Min. Metall. Pet. Engg.,</italic> 189, 47-52.</mixed-citation></ref>
<ref id="R949"><mixed-citation>Rubin, Y., 2003. <italic>Applied stochastic hydrogeology.</italic> Oxford Univ. Press, New York, 416.</mixed-citation></ref>
<ref id="R950"><mixed-citation>Rubin, Y. and Hubbard, S. S., 2005. <italic>Hydrogeophysics.</italic> Water Science and Technology Library, 50, Springer, 521.</mixed-citation></ref>
<ref id="R951"><mixed-citation>Salem, H. S., 1999. Determination of fluid transmissivity and electric transverse resistance for shallow aquifers and deep reservoirs from surface and well-log electric measurements. <italic>Hydrol. Earth Syst .Sci.,</italic> 3(3), 421-427. <pub-id pub-id-type="doi">10.5194/hess-3-421-1999</pub-id></mixed-citation></ref>
<ref id="R952"><mixed-citation>Sattar, G. S., Keramat, M. and Shahid, S., 2016. Deciphering transmissivity and hydraulic conductivity of the aquifer by vertical electrical sounding (VES) experiments in Northwest Bangladesh. <italic>Appl. Water Sci.,</italic> 6, 35. <pub-id pub-id-type="doi">10.1007/s13201-014-0203-9</pub-id></mixed-citation></ref>
<ref id="R953"><mixed-citation>Schwartz, W. F. and Zhang, H., 2004. <italic>Fundamentals of groundwater.</italic> Wiley, New York, 583.</mixed-citation></ref>
<ref id="R954"><mixed-citation>Sen, P. N., Goode, P. A. and Sibbit, A., 1988. Electrical conduction in clay bearing sandstones at low and high salinities. <italic>J. Appl. Phys.,</italic> 63, 4832-4840. <pub-id pub-id-type="doi">10.1063/1.340476</pub-id></mixed-citation></ref>
<ref id="R955"><mixed-citation>Shi, L. and Jiao, J. J., 2014. Seawater intrusion and coastal aquifer management in China: A review. <italic>Environ. Earth Sci.,</italic> 72, 2811-2819. <pub-id pub-id-type="doi">10.1007/s12665-014-3186-9</pub-id></mixed-citation></ref>
<ref id="R956"><mixed-citation>Sikandar, P. and Christen, E. W., 2012. Geoelectrical sounding for the estimation of hydraulic conductivity of alluvial aquifers. <italic>Water Resour. Manag.,</italic> 26(5), 1201-1215. <pub-id pub-id-type="doi">10.1007/s11269-011-9954-3</pub-id></mixed-citation></ref>
<ref id="R957"><mixed-citation>Slater, L., 2007. Near surface electrical characterization of hydraulic conductivity: from petrophysical properties to aquifer geometries-A review. <italic>Surv. Geophys.,</italic> 28, 169-197. <pub-id pub-id-type="doi">10.1007/s10712-007-9022-y</pub-id></mixed-citation></ref>
<ref id="R958"><mixed-citation>Soupios, P. M., Kouli, M., Vallianatos, F., Vafidis, A. and Stavroulakis, G., 2007. Estimation of aquifer hydraulic parameters from surficial geophysical methods: A case study of Keritis Basin in Chania (Crete-Greece). <italic>J. Hydrol.,</italic> 338, 122-131. <pub-id pub-id-type="doi">10.1016/j.jhydrol.2007.02.028</pub-id></mixed-citation></ref>
<ref id="R959"><mixed-citation>Ungemach, P., Moslaghini, F. and Duprat, A., 1969. Emphasis in determination of transmissivity coefficient and application in nappe alluvial aquifer Rhine. <italic>Bull. Inst. Assoc. Sci. Hydrol.,</italic> 14(3), 169-190.</mixed-citation></ref>
<ref id="R960"><mixed-citation>Vinegar, H. J. and Waxman, M. H., 1984. Induced polarisation of shaly sands. <italic>Geophysics,</italic> 49(8), 1267-1287. <pub-id pub-id-type="doi">10.1190/1.1441755</pub-id></mixed-citation></ref>
<ref id="R961"><mixed-citation>Ward, S. H., 1990. Resistivity and induced polarization methods. USA <italic>Investigations in Geophysics</italic> <italic>no 5, Geotechnical and Environmental Geophysics</italic> (Society of Exploration Geophysicists), ed. S. H. Ward, 1, 147-189. <pub-id pub-id-type="doi">10.1190/1.9781560802785.ch6</pub-id></mixed-citation></ref>
<ref id="R962"><mixed-citation>Waxman, M. H. and Smits, L. J. M., 1968. Electrical conductivities in oil bearing sands. <italic>J. Soc. Pe. Engg.,</italic> 8, 107-122.</mixed-citation></ref>
<ref id="R963"><mixed-citation>Werner, A. D., 2010. A review of seawater intrusion and its management in Australia. <italic>Hydrogeol. J.,</italic> 18, 281-285. <pub-id pub-id-type="doi">10.1007/s10040-009-0465-8</pub-id></mixed-citation></ref>
<ref id="R964"><mixed-citation>Werner, A. D., Bakker, M., Post, E. V. A., Vandenbohede, A., Lu, C., Ataie-Ashtiani, B., Simmons, C. T. and Barry, D. A., 2013. Seawater intrusion processes, investigation and management: Recent advances and future challenges. <italic>Adv. Water Resour.,</italic> 51, 3-26. <pub-id pub-id-type="doi">10.1016/j.advwatres.2012.03.004</pub-id></mixed-citation></ref>
<ref id="R965"><mixed-citation>Winsauer, W. O. and McCardell, W. M., 1953. Ionic double-layer conductivity in reservoir rock. <italic>Trans. Am. Inst. Min. Metall. Pet. Eng.,</italic> 198, 129-134.</mixed-citation></ref>
<ref id="R966"><mixed-citation>Worthington, P. F., 1975. Quantitative geophysical investigations of granular aquifers. <italic>Geophys. Surv.,</italic> 3, 313-366. <pub-id pub-id-type="doi">10.1007/BF01447858</pub-id></mixed-citation></ref>
<ref id="R967"><mixed-citation>Worthington, P. F., 1993. The uses and abuses of the Archie’s equation: the formation factor – porosity relationship. <italic>J. Appl. Geophys., </italic>30, 215-228. <pub-id pub-id-type="doi">10.1016/0926-9851(93)90028-W</pub-id></mixed-citation></ref>
<ref id="R968"><mixed-citation>Zohdy, A. A. R., 1974. Use of Dark Zarrouk curves in the interpretation of vertical electrical sounding data. <italic>U.S. Geol. Surv. Bull.,</italic> 41, 1313-D.</mixed-citation></ref>
</ref-list>
</back>
</article>
